Description
Our OSMOCLIPS 2825 range is designed for a continuous long-term use and for a maximum working pressure of 28 bars ; please consult our technical services for superior working pressures.
Our housings are compatible with 2.5” spiral membranes. For multi-membranes housings, the inter-connectors (reference 6*) are provided by the membrane supplier.
Our OSMOCLIPS 2140 – 2840 range is designed for a continuous long-term use and for a maximum working pressure of 21 or 28 bars ; please consult our technical services for superior working pressures.
Our housings are compatible with 4″ spiral membranes, only the production end caps are specific, the inter-connectors (reference 8*) are provided by the membrane supplier.
PLASTICON FRANCE will assist the buyer to determine whether this standard housing is suitable or not, according to particular service conditions. The buyer remains responsible for the final choice. Special materials are available on demand.
– Respect the recommendations given in our starting and use procedure (SAV.E.04) and our assembly instructions (SAV.E.08).
– The conveyed fluid can not exceed the temperature of 49°C.
– Change all the seals when disassembling the buffers.
– Do not tolerate leaks or the possibility for the closing systems to be humidified on a regular basis.
For each delivery, a packing list will be included.
For any later spare parts order, the buyer shall refer to this packing list and precise :
– The PLASTICON FRANCE registration number,
– The pressure housing’s reference,
– The part’s designation.
Document : CLIPS 2825 – Ind B – 6th October 2000 – Page 1/3
ASSEMBLY AND MAINTENANCE
WARNING
OSMOCLIPS 2825 | |||
REF | QUANTITY | DESIGNATION | MATERIAL |
1 1 1 1 2 3 4 5 6* | 1 1 1 1 2 2 2 2 0 to 1 | Tube(1 14″ cartridge) Tube(1 21″ cartridge) Tube(1 40″ cartridge) Tube(2 40″ cartridges) O-Ring Buffer | GFRP |
WORKING CONDITIONS |
Mini Use Temperature Maxi Use Temperature Working Pressure : – 7° C : + 49° C : 28 bars : 42 bars |
REFERENCE | L (mm) | Weight (kg) |
1 X 282514 1 X 282521 1 X 282540 2 X 282540 | 426 604 1086 2102 | 0,9 1,2 2,0 3,8 |
Document : CLIPS 2825 – Ind B – 6th October 2000 – Page 2/3
OSMOCLIPS 2140- 2840 | |||
REF | QUANTITY | DESIGNATION | MATERIAL |
1 1 1 1 1 2 3 5 6 7 *8 9 10 | 1 1 1 1 1 2 2 2 1 1 0 to 2 2 2 | Tube(1 14″ cartridge) Tube(1 21″ cartridge) Tube(1 40″ cartridge) Tube(2 40″ cartridges) Tube(3 40″ cartridges) O-Ring Buffer | GFRP P.V.C (for memory) Nitrile |
WORKING CONDITIONS |
Mini Use Temperature : – 7° C Maxi Use Temperature : + 49° C Working Pressure : 21 and 28 bars Test Pressure : 32 et 42 bars |
OSMOCLIPS 2140 | ||
REFERENCE | L(mm) | Weight (kg) |
1 X 214014 1 X 214021 1 X 214040 2 X 214040 3 X 214040 | 496 674 1156 2172 3188 | 2,9 3,7 5,9 10,5 15,1 |
OSMOCLIPS 2840 | ||
REFERENCE | L(mm) | Weight (kg) |
1 X 284014 1 X 284021 1 X 284040 2 X 284040 3 X 284040 | 496 674 1156 2172 3188 | 3,3 4,3 6,9 12,3 17,7 |